Key Specifications / Features

Model No.: Hits: 25

WDM series solar charge controllers are developed for off-grid solar system and battery backup solar system. Maximum Power Point Tracking (MPPT) charging technology can increase 20-30% power usage efficiency of solar panels more than PWM charging technology.
Request a quote Share PDF
Tags:

    Detail Information

    WDM SERIES MPPT CHARGE CONTROLLER

    Auto identification and selection of system voltage
    High performance 32 bits CPU
    Wide PV input voltage range, convenient for system configuration
    MPPT charge mode, increase power usage efficiency of solar panels
    LCD display, intelligent batteries charging status display
    Running status display of solar panels, batteries and loads
    Optional RS485 communication port, convenient for user integration management 
    Over-charge protection, over-discharge protection, over-load protection, short-circuit protection and battery wrong-connecting protection, anti-thunder-stroke protection
     
    Main Specification
    Model WD48-10 WD48-20 WD48-30 WD48-40 WD48-50 WD48-60
    INPUT
    Max. PV Input Voltage 150V
    MPPT Voltage Range 12V 15V - 120V
    24V 30V - 120V
    48V 60V - 120V
    Max. PV Input Power 12V 140 W 280 W 420 W 560 W 700 W 840 W
    24V 280 W 560 W 840 W 1120 W 1400 W 1680 W
    48V 560 W 1120 W 1680 W 2240 W 2800 W 3360 W
    BATTERY CHARGING
    Battery System Voltage 12V/24V/48V auto recognition
    Max. Charging Current 10A 20A 30A 40A 50A 60A
    Charging mode Maximum Power Point Tracking (MPPT)
    Charging method Three stages: Constant Current (MPPT); Constant Voltage; Floating Charge
    Max. Charging Efficiency 99%
    Battery Types Supported Lead Acid Battery, Gel Battery, Flooded Battery, Lithium Battery
    PROTECTION
    Overload Protection 1.5 times rated current 3s overload protection action, automatic recovery in 1 minute
    Output Short Circuit Protection Hardware protection fuses, automatic recovery in 10 minute
    Over Temperature Protection Charging or discharging stopped when controller temperature over 75℃, Charging or discharging recovery when temperature back to 55℃
    OTHERS
    Cooling Method Intelligent Control Cooling Fan
    Comunication Method RS485 Remote Control Optional
    Operating Ambient Temperature  -15℃  - 50℃ Own Consumption < 20mA
    Storage Temperature  -20℃  - 60℃ Protection Grade IP20
    Dimensions 185x135x65mm 240x143x74mm
    Net Weight 1.15 kgs 1.80 kgs
    Packing Information 380x250x520mm,11.0kgs,8pcs 420x310x 270mm,8.0kgs/4pcs
     
    Main Specification
    Model WD48-80 WD48-100 WD96-50 WD96-100 WD192-50 WD216-50
    INPUT
    Max. PV Input Voltage 150V 300V 450V
    MPPT Voltage Range 48V 60V - 120V
    96V 96V - 240V
    192V 192V - 360V
    216V 216V - 360V
    Max. PV Input Power 48V 4480 W 5600 W  
    96V   5600 W 11200 W  
    192V   11200 W  
    216V   12600 W
    BATTERY CHARGING
    Battery System Voltage 12V/24V/48V auto recognition 96V 192V 216V
    Max. Charging Current 80A 100A 50A 100A 50A 50A
    Charging mode Maximum Power Point Tracking (MPPT)
    Charging method Three stages: Constant Current (MPPT); Constant Voltage; Floating Charge
    Max. Charging Efficiency 99%
    Battery Types Supported Lead Acid Battery, Gel Battery, Flooded Battery, Lithium Battery
    PROTECTION
    Overload Protection 1.5 times rated current 3s overload protection action, automatic recovery in 1 minute
    Output Short Circuit Protection Hardware protection fuses, automatic recovery in 10 minute
    Over Temperature Protection Charging or discharging stopped when controller temperature over 75℃, Charging or discharging recovery when temperature back to 55℃
    OTHERS
    Cooling Method Intelligent Control Cooling Fan
    Comunication Method RS485 Remote Control Optional
    Operating Ambient Temperature  -15℃  - 50℃ Own Consumption < 20mA
    Storage Temperature  -20℃  - 60℃ Protection Grade IP20
    Dimensions 280x180x100mm 315x250x108mm 400x300x162mm
    Net Weight 3.7kgs 4.5kgs 5.6kgs 10kgs 11kgs
    Packing 490x350x350mm/4pcs 370x310x340mm/2pcs 460x380x210mm/1pc
    16.0kgs/4 pcs 11kgs/2pcs 13kgs/2pcs 11kgs/1pc 12kgs/1pc
    Warranty 2 years
    Main Specification
    Model RF240-50 RF384-50 RF192-100 RF216-100 RF240-100 RF384-100
    INPUT
    Max. PV Input Voltage 500V 800V 450V 500V 800V
    MPPT Voltage Range 192V 192V - 360V
    216V 216V - 360V
    240V 240V - 400V
    384V 384V - 640V
    Max. PV Input Power 192V   22400 W  
    216V   25200 W  
    240V 14000 W   28000 W  
    384V   22400 W   44800 W
    BATTERY CHARGING
    Battery System Voltage 240V 384V 192V 216V 240V 384V
    Max. Charging Current 50A 50A 100A 100A 100A 100A
    Charging mode Maximum Power Point Tracking (MPPT)
    Charging method Three stages: Constant Current (MPPT); Constant   Voltage; Floating Charge
    Max. Charging Efficiency 99%
    Battery Types Supported Lead Acid Battery, Gel Battery, Flooded Battery,   Lithium Battery
    PROTECTION
    Overload Protection 1.5 times rated current 3s overload protection   action, automatic recovery in 1 minute
    Output Short Circuit Protection Hardware protection fuses, automatic recovery in 10   minute
    Over Temperature Protection Charging or   discharging stopped when controller temperature over 75℃,   Charging or discharging recovery when temperature back to 55℃       
    OTHERS
    Cooling Method Intelligent Control Cooling Fan
    Comunication Method RS485 Remote Control Optional
    Operating Ambient Temperature  -15℃  - 50℃ Own Consumption < 20mA
    Storage Temperature  -20℃  - 60℃ Protection Grade IP20
    Dimensions 400x300x162mm 530x410x162mm
    Net Weight 10kgs 11kgs 14.5kgs 17.5kgs
    Packing 460x380x210mm/1pc 600x490x210mm/ 1pc
    11kgs/1pc 12kgs/1pc 16kgs/1pc 19kgs/1pc
    Warranty 2 years